Field instruments.

Читайте также:
  1. After Katherine Mansfield
  2. Chapters 11-26: Jane's time as governess at Thornfield Hall
  3. Choose and describe control method for the field.
  4. Chronological resume template (pipe line and oil field construction specialist)
  5. Close-Field Monitoring
  6. Coursework 13: Electric and Gravitational Forces and Fields
  7. Cows in the Field

Fact Sheet: Remote Control Centers

Overview:

 

Most pipelines are operated remotely from a centrally located control center. These Remote Control Centers allow for the efficient operation of either a single or a number of the operator’s different pipeline systems from a single location. The operators of the pipeline can control pump starts/stops, valve opening/closing, monitor product movements, monitor leak detection systems, conduct training operations, and otherwise manage staff from a single operations center.

 

Remote Control Center Advantages

Remote control centers provide operators complete operational information of the pipeline system in one location. Typical information includes:

Pipeline mimic / displays. The complete pipeline can be mimicked to provide operator instantaneous visual feedback on the status of any portion of the pipeline; pumps, valve, tanks, etc. These visual schematics include overviews of the entire pipeline system or systems and drill-down screens that take the viewer to an individual location or piece of equipment

Pump, compressor, and other equipment status. Equipment operation can be displayed with status (On/Off) and other critical parameters associated with a piece of equipment such as flow, discharge pressure, vibration, case temperature, etc.

Valve status.

Valve information can be displayed with valve positions (open/throttle/closed) depicted

Alarms and other operational indications are immediately available for operator response where complete system status is known and, in many cases, can be displayed. These can alert the controller to an unusual or abnormal operating situation or remind the controller about upcoming operating changes that need to be initiated

Trending history and other analytical tools and graphical aids are available to assist personnel in their decision-making under routine, abnormal, and emergency conditions.

 

In addition to the display capabilities, a Remote Control Center provides a centralized response-and-control base of operations to facilitate the coordination and response of abnormal or emergency situations. It also provides a centralized base of operations for ongoing maintenance and other field activities occurring on the pipeline system.

Remote Control Center Operation

 

Pipeline systems are typically operated from computerized control centers, which coordinate operations throughout the system. To allow for this coordinated control, data from the entire pipeline system must be transferred from the field locations to the central control station. This is accomplished by use of:

Field instruments.

Pipeline operating parameters are monitored on a continuing basis by field instruments local to the pipeline. The data from these instruments must be retrieved and assembled for transfer to the Remote Control Center. This is accomplished by Remote Terminal Units (RTU).

Remote terminal units (RTU) are the collection point for the field devices providing the information to the Remote Control Center. This will include pipeline instrumentation such as flow, pressure, temperature, and density, tank levels, and other information such as pump operating/stopped, valve open/closed, etc. Analog data such as pressure, temperature, density and flow must be digitized for ease of transmission to the Remote Control Center. This is accomplished by the RTU. The data from the RTU is transmitted to the Remote Control Center on a pre-determined frequency Normal data transmission may be based on regular transmissions such as 5 or 15 second intervals or when the data has changed from the previous transmitted data, e.g. change of position of a valve.


Дата добавления: 2015-10-30; просмотров: 111 | Нарушение авторских прав


Читайте в этой же книге: Об'єкт управління державними організаціями. | Прямі та зворотні управлінські зв’язки. | Система управління державними організаціями, її структура та зміст. | Функції управління, управлінський цикл, їх роль та місце в управлінській діяльності. | Організація вирішення управлінських задач за допомогою управлінського циклу. | Форми і методи менеджментк держ о-цій | Розробка стратегії розвитку державних організацій | Розробка і прийняття управлінських рішень у МДО | Організація виконання прийнятих управлінських рішень у МДО |