Студопедия
Случайная страница | ТОМ-1 | ТОМ-2 | ТОМ-3
АрхитектураБиологияГеографияДругоеИностранные языки
ИнформатикаИсторияКультураЛитератураМатематика
МедицинаМеханикаОбразованиеОхрана трудаПедагогика
ПолитикаПравоПрограммированиеПсихологияРелигия
СоциологияСпортСтроительствоФизикаФилософия
ФинансыХимияЭкологияЭкономикаЭлектроника

Electrical Safety

Structural organization of the electronic textbook | Electronic textbook as means of remote learning | The electronic textbook on the discrete mathematics. Methodical methods of their use in training in the discrete mathematics | Relations and their properties | Problem definition | Development of systems of testing and monitoring of knowledge of pupils | Options of creation of lessons with use of the electronic textbook | Reasons for need of development of the Electronic textbook on the discrete mathematics | Calculation of labor input of creation of a software product | Calculation of a salary of the programmer |


Читайте также:
  1. About safety of NPP.
  2. About safety of NPP.
  3. AIRCRAFT BREAKDOWN – ELECTRICAL
  4. An Electrical Circuit and Its Elements
  5. Basic Safety Precautions for Working Onboard Machinery Spaces
  6. Distress, urgency and safety signals
  7. Electrical Conduction

All electric equipment has to have reliable protective grounding or zeroing according to requirements of Rules of the device of electro installations.

(http://www.znaytovar.ru/gost/2/RD_164072000_Elektrooborudovan.html)

Grounding devices of electro installations have to conform to requirements P O-95120-001-94 SWEAT.

To grounding (zeroing) are subject:

- cases of electric cars, transformers, devices, lamps, etc.;

- drives of electric devices;

- secondary windings of measuring transformers;

- frameworks of distribution boards, instrument assemblies, guards and cases, and also removable or opening parts if on the last the alternating-current electric equipment over 42 V is established;

- metal designs of distributing devices, metal cable designs, metal cable pipe connections, metal envelopes of wires and armor of control and power cables, metal sleeves and electrical harness pipes, casings and supporting frameworks of bus wires, trays, a box, other metal designs on which the electric equipment is established;

- metal cases mobile and figurative electro receivers;

- the electric equipment placed on moving parts of cars and mechanisms.

Grounding devices have to ensure safety of people and protection of electro installations, operational duties. For that part of electric equipment which can appear alive owing to isolation violation, reliable contact with the grounding device or with grounding designs on which it is established has to be provided.

(http://www.znaytovar.ru/gost/2/NormyNormy_ustrojstva_setej_za.html)

Use of the earth as a working or zero wire is forbidden.

An instrumental inspection of a condition of protective grounding (zeroing) has to be carried out at least once a year, and also after installation or repair.

For ensuring electrical safety it is necessary to keep the following requirements:

- the design of the production inventory put in action by electric energy, has to turn on the device (means) for ensuring electrical safety;

- in inventory protection against casual heating at has to be provided to the parts which are alive;

- handles, levers and inventory buttons which touch with hands at normal operation, should not appear alive at isolation damage. To make measurement of an insulation resistance according to the Rules P O-95120-001-94 SWEAT;

- the inventory supplied with a cord of a delivery, has to have such fastening of cords at which they would not be stressed also to twisting in places of their accession in inventory and isolation of wires would be protected from an attrition;

(http://www.znaytovar.ru/new2673.html)

- tension has to be applied to power supply of lamps of the common irradiating not higher than 380/220 In alternating-current at the earthed neutral and not higher than 220 alternating-current V at the isolated neutral;

(http://www.znaytovar.ru/gost/2/GOST_1767782_Svetilniki_Obshhi.html)

- it is necessary to apply tension to a delivery of separate lamps not higher than 220 V. V rooms without the increased danger the specified tension it is allowed for all stationary lamps irrespective of height of their installation;

- on the front and inverse parties of each panel of distribution boards there have to be the legible inscriptions specifying number of a board and the devices installed on the panel and the equipment, and also tension and a current sort belong to what line or the unit;

- doors of rooms of electro installations (boards) have to be constantly locked;

- installation and cleaning of lamps, change of the fused electro lamps and repair of an electrical network have to be carried out at a removed stress;

- advertising irradiating, the gas-light installations feeding them transformers, store show-windows, etc. have to correspond to the Rules P O-95120-001-94 SWEAT.

 

 


Дата добавления: 2015-11-16; просмотров: 47 | Нарушение авторских прав


<== предыдущая страница | следующая страница ==>
General running costs| Fire safety. Reasons of emergence of a fire

mybiblioteka.su - 2015-2024 год. (0.005 сек.)