4-6 Performing a Sensitivity Analysis Getting Started Building and Running a Process Model
Do not close the dialog box. Instead, define the next variable,
QREB.
7 In the Variable name field, select <New>.
Note: You can also right-click on the Variable name field and
from the shortcut menu, select Create.
The New Item dialog box appears.
8 Type QREB and click OK.
Define QREB to be the reboiler duty for Block B1.
9 In the Category area, select Blocks.
10 In the Type field, select Block-Var.
11 In the Block field, select B1.
12 In the Variable field, select REB-DUTY.
13 Click Close.
You have now defined QCOND and QREB to be the condenser
duty and reboiler duty for block B1.
The Model Analysis Tools | Sensitivity | S-1 | Input | Define
sheet reappears with the three defined calculated variables, XMCH,
QCOND, and QREB listed.
Next, specify the range, increment size, and label for the phenol
flow rate manipulated variable.
1 Click or click the Vary tab.
The Model Analysis Tools | Sensitivity | S-1 | Input | Vary
sheet appears.
Define the phenol flow rate (Stream 2) to vary from 1200
lbmol/hr to 2000 lbmol/hr in increments of 100 lbmol/hr.
2 In the Variable number field, select 1.
3 In the Type field, select Stream-Var.
4 In the Stream field, select 2.
5 In the Variable field, select MOLE - FLOW.
6 In the Values for varied variable area, select Overall range
and enter the following values: