Читайте также:
|
|
Number of stages 22 —
Condenser Total —
Distillate rate 200 lbmol/hr
Reflux ratio 8 —
Accept the defaults in the Reboiler, Valid phases, and
Convergence fields.
Getting Started Building and Running a Process Simulation Model 3-17
The blue checkmark on the Configuration tab indicates the sheet
is complete:
3 Click or click the Streams tab.
The Blocks | B1 | Setup | Streams sheet appears.
In the RadFrac model, there are N stages. Stage 1 is the top stage
(the condenser); stage N is the bottom stage (the reboiler). As
shown in Figure 3.1, the MCH-Toluene feed (stream 1) enters
above stage 14, and the phenol solvent stream (stream 2) enters
above stage 7.
4 Enter 14 in the Stage field for Stream 1.
5 Enter 7 in the Stage field for Stream 2.
6 Accept the defaults for the entry point conventions for the feed
streams and for the locations and phases of the product streams.
The Blocks | B1 | Setup | Streams sheet is complete:
3-18 Building and Running a Process Simulation Model Getting Started
7 Click.
The Blocks | B1 | Setup | Pressure sheet appears.
You can enter a stage-by-stage profile, or specify a top-stage
pressure and a pressure drop for the rest of the column. For this
example, use a condenser pressure of 16 psi, and a reboiler
pressure of 20.2 psi. Aspen Plus interpolates the pressure of the
intermediate stages.
8 In the View list, click and select Pressure profile.
9 In the first Stage field, type 1 and then press the Tab key.
10 In the first Pressure field, type 16 and press Tab.
11 In the next Stage field, type 22 and press Tab.
12 In the next Pressure field, type 20.2.
13 Accept the default Pressure units (psi).
The completed Block B1 Setup Pressure sheet looks like this:
14 Click.
The Required Input Complete dialog box appears.
Note: You can enter additional specifications on optional input
sheets, or go back to any of the required sheets and make changes.
To see what optional input sheets are available, click Cancel on
the dialog box and scroll through the Data Browser to view all the
folders. The Reactions, Convergence, Flowsheeting Options, and
Model Analysis Tools folders are optional.
Getting Started Building and Running a Process Simulation Model 3-19