Benchmark data: density, ρ=2500 kg/m3;
wall thickness h=180 mm.
Calculate.
1. We define surface density of building envelop:
2. We define amplitude-response curve of building envelop soundproofing.
We must find coordinates of the point В on the amplitude-response curve.
X-coordinate of point (fв) is define in table of the applicable Code Design. It depend of thickness and density of construction.
We define B y-coordinate. It depend of surface density:
Amplitude, Hz | The normal value of insulation | Estimated value insulation | Adverse deviations dB | Offset | Adverse deviations dB |
100 | 33 | 36 | + | 29 | + |
125 | 36 | 36 | 0 | 32 | + |
160 | 39 | 36 | -3 | 35 | + |
200 | 42 | 36 | -6 | 38 | -2 |
250 | 45 | 38 | -7 | 41 | -3 |
315 | 48 | 40 | -8 | 44 | -4 |
400 | 51 | 42 | -9 | 47 | -5 |
500 | 52 | 44 | -8 | 48 | -4 |
630 | 53 | 46 | -7 | 49 | -3 |
800 | 54 | 48 | -6 | 50 | -2 |
1000 | 55 | 50 | -5 | 51 | -1 |
1250 | 56 | 52 | -4 | 52 | 0 |
1600 | 56 | 54 | -2 | 52 | + |
2000 | 56 | 56 | 0 | 52 | + |
2500 | 56 | 58 | + | 52 | + |
3150 | 56 | 60 | + | 52 | + |
Amount of adverse deviation | -65 | -4 | -24 |
If amount of adverse deviation more than 32dB, then appraisal curve shifts on 4 dB, that amount of adverse deviation was less than permissible value.
Index value of insulation is y-coordinate of offset appraisal curve on 500Hz.
We get the index value equal to insulation 48 dB. This reinforced panel is satisfies the requirements of sound insulation.
Дата добавления: 2015-08-05; просмотров: 88 | Нарушение авторских прав
<== предыдущая страница | | | следующая страница ==> |
Architectural solution. | | | Татарская музыка |