Читайте также: |
|
Column Operates
Isobarically at 15 psia
To Define the First
Design Specification
3-18 Modeling a Sour Water Stripper Getting Started - Electrolytes
The Design Specs | 1 sheet is complete:
1 From the Data Browser, select the Design Specs folder.
The Design Specs object manager appears.
2 Click New.
3 In the Create new ID dialog box, click OK to accept the
default ID of 2.
A new Design Specs | 2 | Specifications sheet appears.
4 In the Type field, select Stage temperature.
5 In the Target field, enter 190 F.
6 In the Stage field, enter 1.
7 Click to continue.
The Vary Object Manager appears.
Define two manipulated variables to meet the two design
specifications. In this simulation keep free the steam feed rate
and the reflux ratio specifications provided on the Blocks | B1 |
Setup sheet. Aspen Plus adjusts the steam feed rate and reflux
ratio to achieve the NH3 bottoms concentration specification
and the condenser temperature specification.
1 Click New and then click OK.
The Vary | 1 | Specifications sheet appears.
On this sheet, specify which input variables you want to keep
free in order to meet the design specifications you provide.
2 In the Type field, select Feed rate.
To Define Another
Design Specification
To Define the First