Читайте также: |
|
The Streams | SOURWAT | Input | Specifications sheet appears.
Aspen Plus requires two thermodynamic specifications and enough
information to calculate the molar flow rate of each component.
1 Enter the following data:
Temperature 190 F
Pressure 15 PSI
Total flow Mass 10000 LB/HR
2 In the Composition field, click and select Mass-Frac.
3 Enter the following mass fraction values:
H2O 0.997
NH3 0.001
H2S 0.001
CO2 0.001
4 Click to continue.
The Streams | STEAM | Input | Specifications sheet appears.
5 In the Temperature field, click and select Vapor fraction.
Getting Started - Electrolytes Modeling a Sour Water Stripper 3-15
6 Enter the following data:
Vapor fraction 1
Pressure 15 PSI
Composition Mass-Flow
H2O Mass flow value 2000 LB/HR
7 Click to continue.
Specifying the RadFrac Block
The Blocks | B1 | Setup | Configuration sheet appears.
1 Click, then click the words Operating specifications on
the Configuration sheet.
2 Click the link Operating Specifications Descriptions.
3 Review the types of specifications, then when you are ready to
continue, close the Help window.
4 On the Blocks | B1 | Setup | Configuration sheet, enter the
following:
Number of stages 10 (9 theoretical stages and condenser)
Condenser Partial-Vapor
Reboiler None
To Review the Types
Of Specifications that
You Can Make for