NEMA 1-15 style 5-receptacle outlet

AC power plugs and socket-outlets | Multi-standard socket-outlets | Single phase electric stove plugs and socket-outlets |


Читайте также:
  1. AC power plugs and socket-outlets
  2. Correlation of style, norm and function in the language
  3. Fill in the chart below to describe the lifestyle of Chris Strahorn, David Kerley and Dylan Greiner.
  4. Functional styles of the English language
  5. GRAMMAR AND STYLE
  6. Management Styles
  7. Multi-standard socket-outlets

1.6 Unusual American 5-receptacle NEMA 1-15 style outlet, ca. 1928

This is a very rare 5-way outlet from c. 1928, and is able to accept modern ungrounded polarized NEMA 1-15 plugs because the outlet is polarized. The outlet is still obsolete as the NEMA standard only provides for having at most 3 outlets from a single wallplate.

 

American 240 V "Australian" style

1.7 Left: American "Australian" style duplex outlet

Right: Compatibility of American and Australian 240 V plugs

The American electrical supply manufacturers Hubbell, Eagle, and possibly others made outlets and plugs that would match Australian plugs and socket-outlets exactly. These American outlets date back to at least 1915 (as seen in US Patent 1,179,728 filed in 1915[47]), antedating the NEMA 5-15 outlets and plugs. They were meant for appliances requiring grounded 120 V, 15 A service, such as washing machines and gas dryers (to power the motor) for use in wet locations such as laundry rooms.

Split current/voltage ratings

Many older North American receptacles have two different current and voltage ratings, most commonly 10 A 250 V/15 A 125 V. This has to do with a peculiarity of the National Electrical Code from 1923 to the 1950s. Originally, receptacles were rated at 10 A 250 V, because the NEC limited lighting circuits to 10 A. In 1923, the code changed to allow lighting circuits to be fused at 15 A, but the previous 10 A rule still applied to circuits over 125 V.[48] The higher voltages were rarely used for lighting and appliances. Most receptacles with this rating are of the "T-slot" type.